Best products from r/refrigeration

We found 24 comments on r/refrigeration discussing the most recommended products. We ran sentiment analysis on each of these comments to determine how redditors feel about different products. We found 37 products and ranked them based on the amount of positive reactions they received. Here are the top 20.

4. Cooluli Mini Fridge Electric Cooler and Warmer AC/DC Portable Thermoelectric System, Compact Refrigerator, 15 Liter/18 Cans, Pink

    Features:
  • Forget a Cooler full of ice: the thermoelectric system in the Cooluli Cooler and warmer allows for easy switching from Beverage Cooler to food warmer! ideal for use on camping and road trips, picnicking, or for people who spend time in their vehicles. Keep your drinks cold and refreshing, no ice Necessary! not to mention it holds up to 18 12-ounce cans or whatever else you want to bring on your next road trip.
  • Easy switch from cooling to heating: take the Cooler/warmer on the go and transition from cooling to heating with the flip of a switch! easily Fits in the back seat and Plugs into the cigarette lighter with the included 6 and a half foot DC power cable to reach the back seat in any car regardless of the size. Cab and truck drivers love our product to keep them on the road and avoid wasting time and money at rest stops.
  • Ac/DC adapters included: the Cooluli Cooler & warmer comes included with AC and DC power adapters – easy to go from indoor 110V (AC) to car use by plugging the appliance into the car cigarette 12V (DC) adapter. The AC wire is 6 ft. Long and the DC wire is 6 and a half ft. So Finding an outlet won’t be a problem. Also great for use on boats, rvs and while camping or picnicking.
  • Durable design for Travel: the Cooluli 15L Cooler & warmer is designed with car Travel in mind. Built from high quality, sturdy plastic meaning it's lightweight and easy to carry even when full. The Cooler is very well insulated and will keep beverages and food cool or Warm for a good deal of time after the Cooler/warmer is unplugged. This Cooler/warmer is essential for anyone who loves taking road trips or going camping!
  • Thermoelectric cooling system: thermoelectric cooling shouldn’t be confused with refrigeration. Instead of blowing Freon with a fan (refrigeration) the Cooluli electric Cooler & warmer blows air from the metal inside to the outside with the help of an electric fan. This means the Cooler/warmer is 100% safe and Freon free. Since thermoelectric cooling works without refrigerants the Cooluli Cooler & warmer is also !
Cooluli Mini Fridge Electric Cooler and Warmer AC/DC Portable Thermoelectric System, Compact Refrigerator, 15 Liter/18 Cans, Pink
▼ Read Reddit mentions

Top comments mentioning products on r/refrigeration:

u/Adventurepew · 5 pointsr/refrigeration

Learn the local supply shops, even just a quick brush up so you can run for parts fast. knowledge of pipe and valve sizes, type of pipe and valves, this depends on the site, could be schedule 80 pvc, could be steel, could be copper.

learn the local coffee shop, and how to take orders. xl black coffee creams and sugars on the side is a safe bet.


remember that safety can be your largest priority, some sites you can be fired for not wearing gloves, a hard hard, or safety glasses (even just walking out of the job shack) make sure you know the rules of the site and each site will be different. This will be a large change from residential.

pad of paper and pen at all times. home depot and few places have side holsters for tape measures / pens, best thing ever. small pocket flashlight if working indoors the lights can go off randomly or rooms can be unlit.


depending on the type of construction, industrial ammonia can be a lot of watching a welder work (fire watch) and helping them setup. learn everything you can and make there job easy.

ive worked on construction of industrial ammonia cold storage buildings, and ice arenas, as an apprentice.

Depending on the area you work in, watch out for job tool boxes. leave minimal tools on site overnight unless work provided. those things love to walk off.

Congrats on the new job, let me know if you have any questions.

book on refrigeration, if you want to brush up on theory it covers everything.
https://www.amazon.com/Modern-Refrigeration-Conditioning-Andrew-Althouse/dp/1619601990








u/theredkrawler · 7 pointsr/refrigeration

Without tools, the best you can really do is look for oiliness on the pipe. When you find a joint that feels oily (look for dark colours on the pipe, usually covered in very fine dust. Once you rub the dusty area with your fingers you'll feel the oiliness), spray/pour a small amount of washing up liquid over it and look for bubbles. If there's any refrigerant left in the system, you'll usually see bubbles appear (or over a longer period, foam). Of course if the gas has all escaped already - and we're only talking a couple of hundred grams here - then you won't see any bubbles.

Most domestic gear has no access fitting at all so even locating the leak can be difficult if there's no visual indication. You need to get pressure in there so you can leak test - this means adding a bullet piercing valve (like this).

Then you need to put something in via your bullet piercing valve to raise the system pressure. It's best to use dry nitrogen to leak test to save wasting refrigerant, but since you most likely don't have that on hand you could buy yourself some refrigerant (most likely R134a) and pressurise with that. That's a big no-no here (both disposable cylinders and dumping gas to atmosphere by charging a system with a known leak) but I'm guessing your in the US, and those sorts of laws seem remarkably lax so go for gold. It's not like you'll be ruining MY ozone layer too, right? ;)

You also need to regulate the pressure going in to the system. This is where you need gauges. Connect the yellow line to your bottle, connect the blue line loosely to your bullet piercing valve, purge from cylinder to piercing valve by opening the cylinder tap + gauges tap, and releasing some pressure via the loose fitting, then tighten the fitting and close your gauges tap. Open the bullet piercing valve. Open the gauges tap slowly and give it ~50psi of system pressure.

Then you can go for gold with your soap, or you can lash out and grab yourself some "proper" leak detection fluid (like this), or better yet an electronic leak detector (like this one).

Once you've found your leak, you want to release your nitrogen (or reclaim your refrigerant using a reclaim plant and a spare cylinder), then repair it using an oxy/acetalyne set, or since it's only tiny pipework you can get away with a MAPP gas set.

If it's a copper->copper joint, you're laughing - polish the pipework up with emery cloth, heat the pipe until it's just this side of glowing red, and feed the joint with brown tip silver solder.

If it's a copper->steel joint, then it's a bit more of a pain. You need blue tip silver solder and flux. Clean your joint with the emery cloth, give it a nice coating of flux on every surface you need solder to stick to, then heat it up until it's a fair way short of glowing red. Feed the blue tip solder in and STOP. Unlike brown tip (15% silver) you can't just keep feeding blue tip (45% silver) as it ruins the weld.

Now, since you put on a bullet piercing valve and they leak like a sieve in the long term, we need to replace that with a schrader access valve. Since it's most likely going to be in a straight through piece of pipe, you can save time and grab yourself a pre made access valve in 1/4" pipe. Cut away the hole left by the bullet piercing valve, polish the copper and cut the pipework with a ~10mm gap using a tube cutter. Then slip your access fitting assembly in there, and follow the copper->copper joint procedure.

Of course, now that we've done all that you need to change the liquid line filter drier too. I'd recommend a 1/4" solder in core drier in place of the original copper spun drier because... well, copper spun driers are terrible. Follow the pipe cutting procedure from the piercing valve instructions and the soldering instructions from the copper->copper joint instructions and that's done too. Remember - always try and mount the drier so it's outlet is LOWER than its inlet. This turns the drier into a small liquid receiver and helps ensure a good liquid seal over the capillary tube. Speaking of capillary tubes, if it was inserted straight into the original copper spun drier CUT the capillary, don't try and unsweat it. The chances of blocking it up are about 82.5634% (approximately) when you unsweat capillarys. You're much better off chopping it with a set of capillary tube cutters and ensuring a good clean capillary. The ~30mm of wasted capillary will affect performance, but almost certainly not to any sort of measurable degree.

Then give the system a good evacuation using a vacuum pump and ensure it reaches a good vacuum (sub-500 micron) with a digital vacuum gauge.

Then using a set of electronic scales, charge your freshly evacuated system (remembering to purge!) to the charge recommended by the manufacturer.

Voila! You have just fixed your chest freezer.

..... Alternatively, pay someone to do it for you and/or recycle the components and buy yourself a new one.