#10 in Smoke detectors & fire alarms
Use arrows to jump to the previous/next product

Reddit mentions of First Alert RM4 Smart Relay

Sentiment score: 1
Reddit mentions: 3

We found 3 Reddit mentions of First Alert RM4 Smart Relay. Here are the top ones.

First Alert RM4 Smart Relay
Buying options
View on Amazon.com
or
    Features:
  • Activates auxiliary devices when alarm device sounds
  • Works with compatible BRK and First Alert smoke, heat, and carbon monoxide detectors
  • 120V AC powered
  • Enhances the effectiveness of your detector alarm
  • Great for adding a strobe light, siren, bell, door closer, or similar device
  • Faster turnarounds on job sites with the easy-to-install, most-trusted alarms in home safety
Specs:
Color1.5
Height1.5 Inches
Length3.5 Inches
Number of items1
Weight0.14 Pounds
Width0.1 Inches

idea-bulb Interested in what Redditors like? Check out our Shuffle feature

Shuffle: random products popular on Reddit

Found 3 comments on First Alert RM4 Smart Relay:

u/jerobins · 4 pointsr/esp8266

This is the polar opposite of SMD, but I thought I'd share my solution...

While I love DIY, smoke detectors are important. I wanted to interface with my home system but without compromising the integrity of the system.

Get a 120v first alert.
First Alert SA521CN Wireless Interconnected Hardwired Photoelectric Smoke Alarm with Battery Backup https://www.amazon.com/dp/B000EVO9D4

Get the smart relay interconnect.
BRK RM4 Smart Relay for First Alert https://www.amazon.com/dp/B0039PF21U
This includes schematic for wiring to the detector and the color codes for NO/NC relay connection.

~~Get an optocoupler or isolation relay. Mains Voltage! The output of the RM4 is 120V.
Enclosed AC/DC Power Relay with Protection & De-Bounce. Screw Terminals. 120V Trigger Input. https://www.amazon.com/dp/B017743I7S
The RM4 output powers the relay. The screw terminals connect to the 8266.~~

Get a Esp8266; Flash tasmota firmware. Configure for switch and mqtt. Wire it up.
First Alert is now part of the matrix.

Quick update: Did not need the second relay/optocoupler. The BRK RM4 is an isolated relay. Their docs did not make that perfectly clear so I assumed worst case w/o testing it.

u/AnAffableRobot · 1 pointr/homeautomation

I was able to connect my hardwired smoke detectors to my SmartThings system with a BRK RM4 Relay. I installed it in the junction box behind the detector in my basement. When the alarm sounds it will open its switch. By connecting this switch to the auxiliary contact terminals on a door sensor mounted nearby, my HA system knows that the alarms are sounding. This should also work with any other hub that supports a zwave door switch (read: all of them.)

Here's the magic:
BRK RM4 Smoke Alarm Accessory Relay https://www.amazon.com/dp/B0039PF21U/ref=cm_sw_r_other_awd_-HVLwb9C5KFTY

And the door switch I'm using:
Ecolink Z-Wave Door/Window Sensor (DWZWAVE2-ECO) https://www.amazon.com/dp/B00HPIYJWU/ref=cm_sw_r_other_awd_qKVLwbPRVRM5Y

u/patcheudor · 1 pointr/3Dprinting

First setup heater mintemp in the firmware:

http://forum.seemecnc.com/viewtopic.php?t=9763

For added protection I have a smoke detector in the cabinet connected to a relay which cuts the power if the detector goes off:

https://www.amazon.com/BRK-Brands-RM4-Smart-Relay/dp/B0039PF21U