Reddit mentions: The best range replacement plug receptacles
We found 10 Reddit comments discussing the best range replacement plug receptacles. We ran sentiment analysis on each of these comments to determine how redditors feel about different products. We found 6 products and ranked them based on the amount of positive reactions they received. Here are the top 20.
1. 5 Pcs 3P IEC 320 C14 Male Plug Panel Power Inlet Sockets Connectors
- Product Name : Power Inlet Socket;
- Power Supply : AC 250V 10A;
- Plug Type : IEC 320 C14Pins Number : 3;Mounting
- Type : Screw Type;
- Mounting Size : 2.7 x 2 x 2.1cm / 1.1" x 0.8" x 0.83" (L*W*T)
Features:
2. Inlet Module Plug Fuse Switch Male Power Socket 10A 250V 3 Pin IEC320 C14
- Product Name : Power Socket w Switch Fuse
- Material (External) : Plastic, Metal
- Color : Red, Silver Tone, Silver Tone
- Voltage & Current : 10A, 250V AC
- Plug Type : 3 Pin IEC320 C14
Features:
3. 14-30P 4-Pin Male Dryer Plug To 6-15R 3-Prong Female Socket Receptacle Outlet Electric Power Cord Cable Adapter/Converter NEMA 220/250V input 220/250V Output. FX837
- The USB charging cable has Gold plated connectors for anti-oxidation,corrosion resistance, provides best possible quality, high transmission performance
- Replacement data syc USB cable work with Wacom Intuos CTL480 CTL490 CTL690 CTH480 CTH490 CTH680 CTH690 and Wacom Bamboo CTL470 CTL471 CTL671 CTL680 CTH470, ect.
- This power charger cord is capable of charging your device from power source such as PC, Laptop, USB Wall Charger outlet, or USB Car Charger, providing e faster charging speed
- Charging and data transfer cable, high quality material cable with a magnetic ring, good shielding effect
- 60 days no reason money-back service for all Arzweyk customers, We're always willing to listen to your concerns, So please not hesitate contact us
Features:
4. Power Adapter for Gas Range by Canada Wire
- SAFELY Converts 220V to 110V for Gas Ranges
- BIG SAVINGS since you won't need to have it professionally installed
- SIMPLE INSTALLATION - Plug the converter in and you're done
- BUILT-IN 15 Amp fuse for Safety
Features:
5. Leviton 8300-HW 20-Amp, 125-Volt, Heavy Duty Hospital Grade, Duplex Receptacle, Straight Blade, Self Grounding, White
- Interlocking Thermoplastic Nylon Cover and Body
- Nickel- Plated Brass Strap with Integral Ground Contacts
- 15-20 Amp Duplex & Single Configurations Available
- Permanent "Green Dot" Marked on Face. Total Outlet: 2
- Exclusive V-shaped, serrated back-wiring clamps for superior contact
Features:
Specs:
Color | White |
Height | 4.13 inches |
Length | 1.74 inches |
Number of items | 1 |
Weight | 0.1 Pounds |
Width | 1.09 inches |
🎓 Reddit experts on range replacement plug receptacles
The comments and opinions expressed on this page are written exclusively by redditors. To provide you with the most relevant data, we sourced opinions from the most knowledgeable Reddit users based the total number of upvotes and downvotes received across comments on subreddits where range replacement plug receptacles are discussed. For your reference and for the sake of transparency, here are the specialists whose opinions mattered the most in our ranking.
Hey!
So, I know this isn't 'conventional' water/liquid cooling, but I am not sure what's the right place to ask.
I've recently gotten "re-interested" in mineral oil cooling. Back in the gap, Pudget Systems was trying to refine the idea of mineral oil cooling. I've tried to gain insight from their writing but some of it is vague.
My first question pertains to oil "climbing" out of the enclosure via cables:
>The custom motherboard tray also allows us to install a power socket, and a control valve for the air hose. These connection points serve a distinct purpose! By not running any cables directly into the oil, we prevent wicking.
I can't really see what's going on in their pictures. It almost looks like the motherboard I/O is just barely sticking out the top of the mineral oil. Their power cable solution looks similar to what I was thinking: Using some sort of plug/cable like this secured to the case with a rubber gasket to help seal the oil in.
Would "plug extensions" of this sort combined with a gasket form a good enough seal to prevent mineral oil leaking/climbing/wicking? Do you think I can find similar extensions and gaskets for Ethernet, USB, and other kinds of cables?
Will wireless peripherials/receivers work if submerged in mineral oil?
Are there any special considerations I should make when selecting pumps, tubes, radiators, or reservoirs for a mineral oil system?
How do you think the cost of mineral oil vs traditional liquid cooling compares?
If I remember correctly it is 22V. And sorry to say I don't have link for the socet/fuse as I just picked it up from a local electronics store. But this one is quite close to mine. A bit more "Chinease" but anyway hope it helps. https://www.amazon.com/Inlet-Module-Switch-Socket-IEC320/dp/B00F4MFMXE
So for 240V it's two 120V lines in parallel. A dryer outlet should be 240V 30A with two 120V lines (red and black), a neutral (white), and a ground (green). The Foundrywired for 240V with the correct fuses, as seen in the manual will be two 120V lines and a ground. My guess is you'd need something like this with a male adapter end like this on your Foundry.
If you can get the correct ends you could make all these yourself relatively easily. However, I'd only say to do that if you're comfortable working with electrical components yourself. Also I'm not an electrician, but I did wire up my DIY brewery and have converted a table saw from 120V to 240V so I do have a bit of experience with it.
Assuming you have room for it behind your range there is an adapter you can buy to make it easy on yourself.
https://www.amazon.ca/Canada-Wire-Range-Power-Adapter/dp/B01M6ZLQXC
Check your breaker box and see if it's a 20A or 15A breaker. If it's a 20A, you can replace these outlets with the 5-20 outlet and get ~1mph extra charge if you also get the 5-20 adapter from Tesla for your UMC (it all adds up when trickle charging).
If your HOA don't let you do this, you can get an adapter (ONLY USE THIS IF YOUR BREAKER IS ACTUALLY 20A!).
I need it for connecting two boxes that have these https://www.amazon.com/Panel-Power-Inlet-Sockets-Connectors/dp/B00843KZP0#Ask on them
You mean like this?
I used these two walkthroughs as guides:
Total estimated cost is ~$500 based on:
Some of these parts may be purchased at your local hardware store for a cheaper price.....
• Dual Digital Display PID Temperature Controller: http://amzn.com/B002PIM3R8
• Solid State Relay w/ Heatsink: http://amzn.com/B005K2IXHU
• PT100 Thermocouple Sensor: http://amzn.com/B008MU0VFY
• Aluminum Project Enclosure Box, Econobox: http://amzn.com/B005T7RPFC
• 3 Pin IEC320 Male Power Socket w/ Switch: http://amzn.com/B00F4MGRRE . TIP - Replace Fuse With F15AL250V.
• GX16-3 Aviation Connector:http://amzn.com/B00FB56T04
• Black - Tamper Resistant Power Receptacle: http://amzn.com/B002L6H414
• Gray - Tamper Resistant Power Receptacle: http://amzn.com/B002L6H428
• IEC320-C13 Power Cord: http://amzn.com/B0012EI6KE
• Rubber Feet: http://ebay.com/itm/351131287090
• Heat Shrink: http://amzn.com/B00EXLLXK8
• Fork Terminal Wire Connectors - Non Insulated ~ 16-14 AWG: http://amzn.com/B00LUUAB94
• Female Disconnect - Non Insulated: http://amzn.com/B0071OXJ5Q
• Insulated Copper Wire ~ 18-14 AWG
• Nuts & Bolts